Why Doesn't a pH Sensor Display pH 7 in Deionised or Distilled Water?

Ph meter

Why Doesn't a pH Sensor Display pH 7 in Deionised or Distilled Water?

Posted on the 4th of May 2023 by Westlab

Have you ever wondered why you couldn't get a consistent pH meter reading on your distilled or deionised water? Here is why:

A pH sensor may not display a pH of 7 in deionized or distilled water for several reasons, even though theoretically, the pH of pure water is 7 at 25°C. Some factors that can cause deviations in the pH readings include:

1. Contamination

The presence of impurities or contaminants, even in trace amounts, can affect the pH of the water. This includes dissolved gasses like CO2, which can react with water to form carbonic acid, lowering the pH.

2. Calibration

pH sensors must be calibrated periodically to maintain their accuracy. If a pH sensor has not been calibrated properly, it may not display the correct pH value.

3. Temperature effects

The pH of pure water is temperature-dependent. At temperatures different from 25°C, the pH of pure water may deviate from 7. For example, at 0°C, the pH is closer to 7.47; at 100°C, it's around 6.14. Ensure that the pH sensor is temperature-compensated, or make adjustments to the reading based on the temperature of the water.

4. Aging electrodes

The performance of the pH sensor electrode may degrade over time, leading to less accurate readings. Regular maintenance, cleaning, and eventual electrode replacement are necessary to ensure accurate measurements.

5. Electrical interference

The presence of electrical noise or interference can cause fluctuations in pH sensor readings. Make sure to use proper shielding and grounding techniques to minimize interference.

How to Ensure Accurate pH Readings?

One recommended method is to use a pH meter with a glass electrode that is calibrated regularly. The sample should be measured in a clean glass beaker or a measuring cylinder, and any potential sources of contamination should be avoided. It is also important to record the temperature of the sample and make any necessary temperature-related adjustments to the pH reading.

You must also remember that water (Deionised or Distilled Water) has no pH of 7. As soon as the water comes in contact with air, CO2 gas dissolves it, forming carbonic acid (H2CO3). This results in the pH being lower than seven.

To measure the pH of water accurately, you will require ''pH Ionic Strength Adjusters.'' These adjust the water's ionic strength without changing its pH, making it possible to determine the accurate pH.

The purpose of a deionizer and distillation unit is to purify the water by substantially reducing its conductivity. This means you should be measuring the conductivity, not the pH.

How to Do Maintenance and Calibration of pH Sensors?

Regular maintenance of pH sensors is crucial for ensuring accurate readings. Over time, the performance of the sensor's electrode may degrade, leading to less accurate measurements. Regular maintenance, cleaning, and eventual electrode replacement are necessary to ensure accurate measurements.

The following are the steps for proper calibration of pH meter sensors:

  • Prepare a calibration solution with a known pH value.
  • Immerse the electrode in the calibration solution.
  • Adjust the reading on the pH meter until it matches the known pH value.
  • Repeat the process with multiple calibration solutions to check the accuracy of the pH sensor over a range of pH values.

Tips for pH Sensor Maintenance

To maintain the accuracy of a pH sensor, it is important to follow these best practices:

  • Store the electrode in a storage solution when not in use.
  • Clean the electrode regularly to remove any buildup of salts or other contaminants.
  • Calibrate the sensor regularly, at least once a month, or more frequently if the readings exceed the expected range.
  • Replace the electrode when it shows signs of degradation or when the readings become consistently inaccurate.

Advanced pH Measurement Techniques

Advanced pH measurement techniques refer to the use of specialized tools and methods to improve the accuracy and precision of pH measurements. Some of the most common techniques are as follows:

1. Use of pH Buffers

pH buffers are solutions with a known, constant pH value used to calibrate pH meters. Using multiple pH buffers in calibration can increase the accuracy of pH measurements, especially over a wide range of pH values.

2. Calibration with Multiple Points

Calibrating a pH meter with multiple points using pH buffers can help increase the accuracy of pH measurements and ensure that the pH sensor functions correctly over a range of pH values.

3. Advanced Electrode Technology

New electrode technologies, such as ion-selective electrodes and optical sensors, offer improved accuracy and stability compared to traditional pH electrodes. Using these advanced electrode technologies can result in more accurate pH readings and improved measurement performance.

Westlab Australia | Your Trusted Laboratory Equipment Provider

At Westlab, we are passionate about facilitating discoveries and advancements in science and medicine. Our range of products, including microscopes, slides, and lab accessories, are designed to help scientists efficiently observe common germs under a microscope. Explore our range of microscopes at Westlab Australia, and let us work towards your next groundbreaking discovery!

Conclusion

Meanwhile, obtaining an accurate pH reading in deionized or distilled water can be challenging due to various factors such as contamination in a given Glass Beaker, calibration, temperature effects, aging electrodes, and electrical interference. To minimize these sources of error and ensure accurate readings, it is important to follow proper measurement techniques, regularly maintain and calibrate the pH sensor, and consider potential sources of contamination or interference.

FAQs

What is a pH sensor used for?

A pH sensor measures the acidity or alkalinity of a solution, typically on a scale of 0-14, where 7 is neutral, less than 7 is acidic, and greater than 7 is alkaline.

How often should a pH sensor be calibrated?

The calibration frequency for a pH sensor depends on factors such as the application, the environment, and the sensor's performance. As a general rule, it is recommended to calibrate the sensor at least once a month or more frequently if the readings are consistently outside of the expected range.

How does temperature affect pH readings?

The pH of a solution is temperature-dependent, and deviations from the expected pH value can occur at temperatures different from 25°C. To minimize this source of error, it is important to measure the temperature of the sample and make any necessary temperature-related adjustments to the pH reading.

Can pH readings be affected by electrical interference?

Yes, electrical interference can cause fluctuations in pH readings. To minimize this source of error, it is essential to use proper shielding and grounding techniques to minimize interference.